* PATH : HOME > Service Manual
 
    
[The check of battery]
¢º Dry-charged battery
  * Storage place : Temoerayure should be low with no humidity(dry) and not direct sunlights.
  * Arrangement : Batteries should be arranged in order to use older manufacturing date code
    (first-in,first-out)
  * Notice on storage : When accumulate them packed with carton box, batteries should be straightly filed
    less than 5pcs according to the indicated marks on box.
    Also, never open plug or take aluminium tape off before electrolyte filling.
   
¢º Wet-charged battery
  * Check the following points before placing them in stock.
  * Charge : Batteries should be fully charged.
  * Level line : The electrolyte should be up to the level indicator in all cells.
  * Sp. Gr: If the sp.gr of battery is lower than standard (means that battery was discharged),
    boosting-charge should be needed.
   
  # Boosting-charge timing
 
Conventional Battery
Mf Battery
One Time / ABT 4 Months
One Time / ABT 6 Months
  # Normally, boosting - charge should be performed whenever sp.gr is 1.230/25¡É

  * Storage place: Temperatyre should be low with no humidity (dry) and not direct sunlights, rain or snow.
  * Arrangement : Same as dry-charged battery. In addition to this, avoid a long storage and batteries
    should be stored to the shelf made of a acid-resistant material including strong strength.
  * Notice on storage : Keep always battery clean. Keep the ventilation hole of battery not close.
  * Prevent short - circuit between terminal and terminal, and keep a fire away form battery.
   
¢º Mf Battery
  * No need of an additional electrolyte filling because this battery is maintence free battery and the
    indication window is located on the cover in order to check battery conditions.
  * According to clolr condition on the indication window,
    Green - normal
    White - Requested to charge
    Red- Requested to add a distilled water
  * If a long storage of battery without boosting charge, abnormal condition (white & red) is to be Happened.
    Pls refer to the article of wet-charged battery in relation to storage place, storage method and boosting-
    charge.
   
Copyright©2002 SUNGWOO AUTOMOTIVE Co.,Ltd.  All Rights Reserved.